ABB SG Series

Reliable and efficient standalone UPS for critical applications

The SG Series is one of the best performing, most reliable and most versatile three-phase UPS systems available to those who need critical power protection. Power peace-of-mind for a wide range of applications is guaranteed - at a low total cost of ownership (TCO).

This true online double conversion UPS exploits its network integration software and communication connectivity to provide comprehensive, easy-to integrate power protection for almost any IT environment. The SG Series operates in VFI (voltage frequency independent) mode, which maximizes load protection at any time. Instead of standard filters, the UPS runs an innovative control algorithm on the IGBT rectifier to ensure the delivery of clean power in a most efficient manner.

The SG Series UPS provides top-class reliability and performance while complying with all relevant EMC and safety standards. ABB’s unique RPA™ technology (redundant parallel architecture) allows units to work in parallel, thus further increasing reliability and uptime.

 Key features:

• eBoost technology for high efficiency - up to 99 percent

• Up to 94.6 percent efficiency

• PurePulse IGBT rectifier: clean input <2 percent THDi

• Output power factor: 1.0 (10-40 kVA), 0.9 (60-600 kVA)

• True front access design

• Small footprint

• Inverter zig-zag isolation transformer

• Extremely low output voltage distortion

• Superior battery management

• Intelligent energy management integrated (IEMi)

• Backfeed protection

• Built-in maintenance bypass

• Parallelable up to six units

Discover more

Edit Content

Plus & features

A comprehensive power solution

Delivering high efficiency with eBoost technology

ABB’s SG Series is one of the most efficient and reliable three-phase UPS systems available, providing outstanding output performance and reliable power protection for your critical application needs. SG Series UPS solutions are designed and optimized to provide high efficiency at part-load conditions too.

  • High efficiency: up to 94.6 percent in double conversion mode and up to 99 percent in eBoost mode. eBoost is available on 160-500 kVA models
  • eBoost operation minimizes losses and can save annual power and cooling costs of up to $300k for a 5 MW data center (based on typical figures)
  • The PurePulse IGBT rectifier keeps your supply network clean and compact by shrinking the circuit breaker, cabling and generator

The SG Series UPS ensures low input current harmonic distortion and excellent output voltage regulation and dynamic response, thus reducing operational costs – all in an environmentally friendly solution.

Easier installation and configuration flexibility

  • True front access for operation and maintenance reduces mean time to repair (MTTR)
  • Small footprint
  • The redundant parallel architecture delivers reliability, redundancy and scalability
  • Up to six UPS frames can be paralleled

High performance and availability

  • Enhanced output performance that protects and supplies even the most sensitive IT loads with a lagging-leading power factor (0.9) without derating
  • Excellent dynamic performance and low output voltage distortion
  • Inverter zig-zag isolation transformer provides outstanding short-circuit capability and load galvanic separation
 
Edit Content

PowerLine DPA IEC - Technical specifications

  • GENERAL DATA

  • System power range (KVA)

  • 10-40; 60-80; 100-120; 160; 200-300; 400-500;

  • Active power / frame (kW)

  • 10/15/20/30/40;   54/72;    90/108;    144;    180/225/270;     360/450

  • UPS output rated PF

  • 0.9

  • Max no of parallel frames

  • Up to 6 frames

  • Max system power

  • Up to 30 modules

  • Max system power

  • 3000 kW

  • Wiring

  • 3ph + N + PE

  • UPS type

  • Three-phase standalone

  • Topology

  • Online double conversion

  • INPUT

  • Nominal input voltage

  • 3 x 380/400/415 V + N 

  • Voltage range

  • 340-460 V

  • Frequency range

  • 45-66 Hz

  • Current THD at 100% load

  • < 3%

  • Power Factor at 100% load

  • ≥ 0.99

  • OUTPUT

  • Rated output voltage
    (load dependent)

  • 3 x 380/400/415 V + N

  • Voltage THD (with linear load)

  • <2% linear load, <3% nonlinear load (EN 62040)

  • Rated frequency

  • 50/60 Hz

  • Efficiency

  • Double conversion

  • Up to
    92.3%

        Up to
        91.9%

        Up to
        92.1%

        Up to
        94.2%

        Up to
        94.6%

        Up to
        94.2%

  • Eco-mode

  • Up to
    98%

        Up to
        97.9%

        Up to
        97.9%

        Up to
        98.4%

        Up to
        98.5%

        Up to
        98.7

  • Communication

  • User interface

  • System graphical display (HMI) + LCD panel UPS Module

  • Communication ports

  • SNMP; ModBus; potential free contacts slot, potential free contacts

  • Software

  • Monitoring and shutdown software available as option

  • Empowering Indonesia with Smart Electrical & IT Solutions.